Follow
Toshioh Fujibuchi
Toshioh Fujibuchi
Faculty of Medical Sciences, Kyushu University
Verified email at hs.med.kyushu-u.ac.jp
Title
Cited by
Cited by
Year
An algorithm for automated modulation transfer function measurement using an edge of a PMMA phantom: Impact of field of view on spatial resolution of CT images
C Anam, T Fujibuchi, WS Budi, F Haryanto, G Dougherty
Journal of applied clinical medical physics 19 (6), 244-252, 2018
402018
Assessment of patient dose and noise level of clinical CT images: automated measurements
C Anam, WS Budi, K Adi, H Sutanto, F Haryanto, MH Ali, T Fujibuchi, ...
Journal of Radiological Protection 39 (3), 783, 2019
322019
An evaluation of computed tomography dose index measurements using a pencil ionisation chamber and small detectors
C Anam, T Fujibuchi, F Haryanto, R Widita, I Arif, G Dougherty
Journal of Radiological Protection 39 (1), 112, 2019
292019
A simple method for calibrating pixel values of the CT localizer radiograph for calculating water-equivalent diameter and size-specific dose estimate
C Anam, T Fujibuchi, T Toyoda, N Sato, F Haryanto, R Widita, I Arif, ...
Radiation Protection Dosimetry 179 (2), 158-168, 2018
272018
Estimate of photonuclear reaction in a medical linear accelerator using a water-equivalent phantom
T Fujibuchi, S Obara, H Sato, M Nakajima, N Kitamura, T Sato, H Kumada, ...
Progress in Nuclear Science and Technology 2, 803-7, 2011
272011
Noise reduction in CT images using a selective mean filter
C Anam, K Adi, H Sutanto, Z Arifin, WS Budi, T Fujibuchi, G Dougherty
Journal of biomedical physics & engineering 10 (5), 623, 2020
252020
Automated MTF measurement in CT images with a simple wire phantom
C Anam, T Fujibuchi, F Haryanto, WS Budi, H Sutanto, K Adi, Z Muhlisin, ...
Polish Journal of Medical Physics and Engineering 25 (3), 179-187, 2019
222019
An improved method of automated noise measurement system in CT images
C Anam, I Arif, F Haryanto, FP Lestari, R Widita, WS Budi, H Sutanto, ...
Journal of Biomedical Physics & Engineering 11 (2), 163, 2021
212021
Comparisons of hounsfield unit linearity between images reconstructed using an adaptive iterative dose reduction (AIDR) and a filter back-projection (FBP) techniques
I Suyudi, C Anam, H Sutanto, P Triadyaksa, T Fujibuchi
Journal of Biomedical Physics & Engineering 10 (2), 215, 2020
192020
Development of a novel artifact-free eye shield based on silicon rubber-lead composition in the CT examination of the head
Y Irdawati, H Sutanto, C Anam, T Fujibuchi, F Zahroh, G Dougherty
Journal of Radiological Protection 39 (4), 991, 2019
192019
Applicability of self-activation of an NaI scintillator for measurement of photo-neutrons around a high-energy X-ray radiotherapy machine
G Wakabayashi, A Nohtomi, E Yahiro, T Fujibuchi, J Fukunaga, Y Umezu, ...
Radiological physics and technology 8, 125-134, 2015
192015
Comparison of neutron fluxes in an 18-MeV unshielded cyclotron room and a 16.5-MeV self-shielded cyclotron room
T Fujibuchi, G Horitsugi, I Yamaguchi, A Eto, Y Iwamoto, S Obara, T Iimori, ...
Radiological physics and technology 5, 156-165, 2012
192012
Automated development of the contrast–detail curve based on statistical low‐contrast detectability in CT images
C Anam, A Naufal, T Fujibuchi, K Matsubara, G Dougherty
Journal of Applied Clinical Medical Physics 23 (9), e13719, 2022
182022
Radiation protection education using virtual reality for the visualisation of scattered distributions during radiological examinations
T Fujibuchi
Journal of Radiological Protection 41 (4), S317, 2021
182021
The impact of head miscentering on the eye lens dose in CT scanning: Phantoms study
C Anam, T Fujibuchi, T Toyoda, N Sato, F Haryanto, R Widita, I Arif, ...
Journal of Physics: Conference Series 1204 (1), 012022, 2019
162019
Distribution of residual long-lived radioactivity in the inner concrete walls of a compact medical cyclotron vault room
T Fujibuchi, A Nohtomi, S Baba, M Sasaki, I Komiya, Y Umedzu, H Honda
Annals of nuclear medicine 29, 84-90, 2015
162015
Development of an application to visualise the spread of scattered radiation in radiography using augmented reality
K Nishi, T Fujibuchi, T Yoshinaga
Journal of Radiological Protection 40 (4), 1299, 2020
152020
Angular dependence of shielding effect of radiation protective eyewear for radiation protection of crystalline lens
Y Hirata, T Fujibuchi, K Fujita, T Igarashi, E Nishimaru, S Horita, R Sakurai, ...
Radiological physics and technology 12, 401-408, 2019
152019
Scatter index measurement using a CT dose profiler
C Anam, F Haryanto, R Widita, I Arif, T Fujibuchi, T Toyoda, G Dougherty
J Med Phys Biop 4 (1), 95-102, 2017
152017
Comparison of central, peripheral, and weighted size-specific dose in CT
C Anam, D Adhianto, H Sutanto, K Adi, MH Ali, WID Rae, T Fujibuchi, ...
Journal of X-ray Science and Technology 28 (4), 695-708, 2020
142020
The system can't perform the operation now. Try again later.
Articles 1–20