Follow
Krzysztof Cieślicki
Krzysztof Cieślicki
Wydział Mechatroniki Politechniki Warszawskiej
Verified email at mchtr.pw.edu.pl
Title
Cited by
Cited by
Year
Biomimetic design of microfluidic manifolds based on a generalised Murray's law
DR Emerson, K Cieślicki, X Gu, RW Barber
Lab on a Chip 6 (3), 447-454, 2006
2052006
Investigations of flow and pressure distributions in physical model of the circle of Willis
K Cieslicki, D Ciesla
Journal of biomechanics 38 (11), 2302-2310, 2005
782005
Hydrocephalus shunts and waves of intracranial pressure
ZH Czosnyka, K Cieslicki, M Czosnyka, JD Pickard
Medical and Biological Engineering and Computing 43, 71-77, 2005
442005
Critical pressure for arterial wall rupture in major human cerebral arteries
B Ciszek, K Cieślicki, P Krajewski, SK Piechnik
Stroke 44 (11), 3226-3228, 2013
252013
Investigations of mixing process in microfluidic manifold designed according to biomimetic rule
K Cieslicki, A Piechna
Lab on a Chip 9 (5), 726-732, 2009
202009
Can the Dean number alone characterize flow similarity in differently bent tubes?
K Cieślicki, A Piechna
172012
Hydrodynamiczne uwarunkowania krążenia mózgowego
K Cieślicki
Akademicka Oficyna Wydawnicza EXIT, 2002
152002
Problems in application of purely linear models in cerebral circulation
SK Piechnik, M Czosnyka, K Cieślicki, D Cieśla
Journal of biomechanics 4 (35), 553-554, 2002
142002
Investigations of the effect of inertia on flow of air through porous bearing sleeves
K Cieslicki
Wear 172 (1), 73-78, 1994
141994
Experimental and numerical modelling of flow in the human cerebral arteries
K Cieślicki
Journal of Medical Informatics & Technologies 7, 2004
122004
Using Murray’s law to design artificial vascular microfluidic networks
RW Barber, K Cieslicki, D Emerson
Design and Nature III: Comparing design in nature with science and …, 2006
112006
Wodogłowie i inne zaburzenia krążenia płynu mózgowo-rdzeniowego u dzieci
K Zakrzewski
Wydawnictwo Czelej, 2007
92007
Spatial anisotropy of permeability in sleeve bearings
K Cieślicki, K Krzeminski
International Journal of Powder Metallurgy 31 (3), 1995
71995
Optimal use of the lumbar infusion test in patients with communicating hydrocephalus. Theoretical considerations in comparison to clinical observations
K Cieślicki, R Czepko
Neurologia i Neurochirurgia Polska 38 (3), 189-195, 2004
62004
Pressure-Flow Relation of Arterial Segments of Variable Geometry
K Cieslicki, A Lasowska, AZ Smolarski
Polish Journal of Medical Physics and Engineering 6, 55-67, 2000
62000
Experimental investigations of steady flow in a tube with circumferential wall cavity
K Cieslicki, A Lasowska
61999
Resistance to the blood flow of a vascular tree–a model study
K Cieslicki
Polish J Med Phys Eng 5, 161-172, 1999
61999
The effect of inertia on flows in tubes with periodic step changes in diameter
K Cieslicki, A Lasowska
Bulletin of the Polish Academy of Sciences, Technical Sciences 43, 423-438, 1995
61995
Two-layered analytical model of arterial wall with residual stress under physiological loading
K Cieslicki, A Piechna, W Gambin
Applied Mathematical Modelling 57, 52-63, 2018
52018
Repeated assessment of suspected normal pressure hydrocephalus in non-shunted cases. A prospective study based on the constant rate lumbar infusion test
R Czepko, K Cieslicki
Acta neurochirurgica 158, 855-863, 2016
52016
The system can't perform the operation now. Try again later.
Articles 1–20