Follow
MOHD SYAHIR MANSOR
MOHD SYAHIR MANSOR
Advance Medical and Dental Institute (AMDI), Penang, Malaysia
Verified email at usm.my
Title
Cited by
Cited by
Year
Impact of PET/CT system, reconstruction protocol, data analysis method, and repositioning on PET/CT precision: An experimental evaluation using an oncology and brain phantom
S Mansor, E Pfaehler, D Heijtel, MA Lodge, R Boellaard, M Yaqub
Medical physics 44 (12), 6413-6424, 2017
402017
Quantification of dynamic 11C-phenytoin PET studies
S Mansor, R Boellaard, FE Froklage, EDM Bakker, M Yaqub, RA Voskuyl, ...
Journal of Nuclear Medicine 56 (9), 1372-1377, 2015
262015
Comparison of HRRT and HR+ Scanners for Quantitative (R)-[11C]verapamil, [11C]raclopride and [11C]flumazenil Brain Studies
FHP van Velden, SM Mansor, DME van Assema, BNM van Berckel, ...
Molecular imaging and biology 17, 129-139, 2015
152015
Characterization of GO: I-131 for radioactive clinical waste water management in nuclear medicine
MKAA Razab, MS Mansor, A Mohamed Noor, NFFA Latif, SM Rozi, ...
Materials Science Forum 1010, 561-566, 2020
142020
Impact of resolution recovery in quantitative 99mTc SPECT/CT cardiac phantom studies
FS Ismail, S Mansor
Journal of Medical Imaging and Radiation Sciences 50 (3), 449-453, 2019
142019
In Vitro and In Vivo Investigation of S1PR1 Expression in the Central Nervous System Using [3H]CS1P1 and [11C]CS1P1
H Jiang, S Joshi, H Liu, S Mansor, L Qiu, H Zhao, T Whitehead, ...
ACS chemical neuroscience 12 (19), 3733-3744, 2021
132021
Accuracy assessment of SUV measurements in SPECT/CT: a phantom study
F Halim, H Yahya, KN Jaafar, S Mansor
Journal of nuclear medicine technology 49 (3), 250-255, 2021
92021
Spatially constrained kinetic modeling with dual reference tissues improves 18F-flortaucipir PET in studies of Alzheimer disease
Y Zhou, S Flores, S Mansor, RC Hornbeck, Z Tu, JS Perlmutter, B Ances, ...
European journal of nuclear medicine and molecular imaging, 1-15, 2021
92021
Phase 1 evaluation of 11C-CS1P1 to assess safety and dosimetry in human participants
MR Brier, M Hamdi, J Rajamanikam, H Zhao, S Mansor, LA Jones, ...
Journal of Nuclear Medicine 63 (11), 1775-1782, 2022
82022
Preliminary study of the potential graphene oxide as radioactive clinical wastewater adsorbability in nuclear medicine
MKAA Razab, MS Manso, SM Rozi, NFF Abd Latif, KN Jaafar, ...
IOP Conference Series: Earth and Environmental Science 596 (1), 012037, 2020
82020
Determination of Rn-222 emanations from kenaf composite brick
M Razab, AM Noor, KNS Wong, NA Mocktar, NA Hikamarhakimi, ...
AIP Conference Proceedings 2068 (1), 2019
32019
Impact of new scatter correction strategies on high-resolution research tomograph brain PET studies
S Mansor, R Boellaard, MC Huisman, BNM van Berckel, RC Schuit, ...
Molecular Imaging and Biology 18, 627-635, 2016
32016
Head‐to‐head comparison of [18F]MK‐6240 and [18F]flortaucipir (AV‐1451) in autosomal dominant Alzheimer disease: Neuroimaging / Optimal neuroimaging …
SE Flores, BA Gordon, Y Su, A Dincer, SJ Keefe, RL Feldman, KE Shady, ...
Alzheimer's & Dementia 16, e044688, 2020
22020
Intra-vendor clinical SPECT/CT system activity validation of 99mTc in phantom studies
M Yousef, S Mansor
Journal of Physics: Conference Series 1248 (1), 012017, 2019
22019
Parametric methods for dynamic 11C-phenytoin PET studies
S Mansor, M Yaqub, R Boellaard, FE Froklage, A De Vries, EDM Bakker, ...
Journal of Nuclear Medicine 58 (3), 479-483, 2017
22017
Revolutionizing cancer treatment by boosting dendritic cell vaccine efficacy with graphene oxide
R Mohamed, MM Ramli, AH Reshak, NH Osman, MY Aziz, MS Mansor
Trends in Immunotherapy 7 (1), 2039, 2023
12023
Experimental evaluation of absolute quantification in 99mTc‐TRODAT‐1 SPECT/CT brain dopamine transporter (DAT) studies
NA Zainudin, N Zulkifli, K Hamid, H Hashim, S Mansor
Journal of Applied Clinical Medical Physics 23 (8), e13723, 2022
12022
Preliminary Human Dosimetry Studies of [11C]-CS1P1, a Novel PET Tracer for Targeting Sphingosine-1-Phosphate Receptor 1 (S1P1)
S Mansor, R Laforest, Z Luo, G Gaehle, M Nickels, T Benzinger, Z Tu
Journal of Nuclear Medicine 62 (supplement 1), 1591-1591, 2021
12021
Validation of 131I activity in thyroid phantom using SPECT/CT 3D image based dosimetry
MHM Yahya, FNA Halim, S Mansor
Journal of Physics: Conference Series 1497 (1), 012031, 2020
12020
Potential of Metal Artifact Reduction (MAR) and Deep Learning-based Reconstruction (DLR) integration in CT Metal Artifact Correction: A review
MM Njiti, ND Osman, MS Mansor, NA Rabaiee, MZA Aziz
Radiation Physics and Chemistry, 111541, 2024
2024
The system can't perform the operation now. Try again later.
Articles 1–20