Multi-exposure laser speckle contrast imaging using a high frame rate CMOS sensor with a field programmable gate array S Sun, BR Hayes-Gill, D He, Y Zhu, SP Morgan Optics letters 40 (20), 4587-4590, 2015 | 30 | 2015 |
A single-chip CMOS pulse oximeter with on-chip lock-in detection D He, SP Morgan, D Trachanis, J Van Hese, D Drogoudis, F Fummi, ... Sensors 15 (7), 17076-17088, 2015 | 26 | 2015 |
Laser Doppler blood flow imaging using a CMOS imaging sensor with on-chip signal processing D He, HC Nguyen, BR Hayes-Gill, Y Zhu, JA Crowe, C Gill, GF Clough, ... Sensors 13 (9), 12632-12647, 2013 | 15 | 2013 |
64× 64 pixel smart sensor array for laser Doppler blood flow imaging D He, HC Nguyen, BR Hayes-Gill, Y Zhu, JA Crowe, GF Clough, CA Gill, ... Optics letters 37 (15), 3060-3062, 2012 | 14 | 2012 |
Comparison of laser Doppler and laser speckle contrast imaging using a concurrent processing system S Sun, BR Hayes-Gill, D He, Y Zhu, NT Huynh, SP Morgan Optics and Lasers in Engineering 83, 1-9, 2016 | 12 | 2016 |
Effect of object size and acoustic wavelength on pulsed ultrasound modulated fluorescence signals NT Huynh, H Ruan, D He, BR Hayes-Gill, SP Morgan Journal of biomedical optics 17 (7), 076008-076008, 2012 | 12 | 2012 |
Complementary metal-oxide-semiconductor imaging array with laser Doppler blood flow processing C Kongsavatsak, D He, BR Hayes-Gill, JA Crowe, SP Morgan Optical Engineering 47 (10), 104401-104401-14, 2008 | 11 | 2008 |
Application of a maximum likelihood algorithm to ultrasound modulated optical tomography NT Huynh, D He, BR Hayes-Gill, JA Crowe, JG Walker, ML Mather, ... Journal of Biomedical Optics 17 (2), 026014-026014, 2012 | 6 | 2012 |
Low resource processing algorithms for laser Doppler blood flow imaging HC Nguyen, BR Hayes-Gill, Y Zhu, JA Crowe, D He, SP Morgan Medical engineering & physics 33 (6), 720-729, 2011 | 6 | 2011 |
Laser Doppler blood flowmetry with FPGA processing C Kongsavatsak, D He, SP Morgan, BR Hayes-Gill, JA Crowe, M Clark ALT'03 International Conference on Advanced Laser Technologies: Biomedical …, 2004 | 6 | 2004 |
Characterization of tissue scaffolds using optics and ultrasound NT Huynh, NG Parker, D He, H Ruan, BR Hayes-Gill, ML Mather, ... Optical Interactions with Tissue and Cells XXII 7897, 274-283, 2011 | 4 | 2011 |
Application of a maximum likelihood algorithm to ultrasound modulated optical tomography NT Huynh, D He, BR Hayes-Gill, JA Crowe, JG Walker, ML Mather, ... Photons Plus Ultrasound: Imaging and Sensing 2011 7899, 262-273, 2011 | 4 | 2011 |
32× 32 pixel array complementary metal-oxide semiconductor imaging sensor for laser Doppler blood-flow measurement D He, C Kongsavatsak, BR Hayes-Gill, JA Crowe, SP Morgan Optical Engineering 50 (5), 054403-054403-11, 2011 | 3 | 2011 |
Full field laser Doppler flowmetry with custom made CMOS sensors D He, N Hoang, BR Hayes-Gill, JA Crowe, Y Zhu, SP Morgan Design and Quality for Biomedical Technologies II 7170, 116-123, 2009 | 3 | 2009 |
Design and simulation of an integrated optical CMOS heart rate sensor D He, C Liu, D Trachanis, JV Hese, D Drogoudis, F Fummi, F Stefanni, ... The Tenth International Conference on Advanced Semiconductor Devices and …, 2014 | 2 | 2014 |
Full field laser doppler blood flow sensor D He University of Nottingham, 2010 | 2 | 2010 |
High-Spatial Resolution Laser Doppler Blood Flow Imaging S Sun, D He, BR Hayes-Gill, SP Morgan Brunel University London, 2014 | | 2014 |
COMBINING OPTICS AND ULTRASOUND TO IMAGE 3 D TISSUE CONSTRUCTS D He, NT Huynh, H Ruan, F Zhang, ML Mather, NG Parker, BR Hayes-Giil, ... International Journal of Artificial Organs 34 (8), 694, 2011 | | 2011 |
Laser Doppler blood flow imaging with a 64x64 pixel full custom CMOS sensor D He, HC Nguyen, BR Hayes-Gill, Y Zhu, JA Crowe, SP Morgan, ... Design and Quality for Biomedical Technologies IV 7891, 40-46, 2011 | | 2011 |