Study of a high-resolution, 3D positioning cadmium zinc telluride detector for PET Y Gu, JL Matteson, RT Skelton, AC Deal, EA Stephan, F Duttweiler, ... Physics in Medicine and Biology 56, 1563-1584, 2011 | 122 | 2011 |
Characterization of a sub-assembly of 3D position sensitive cadmium zinc telluride detectors and electronics from a sub-millimeter resolution PET system S Abbaszadeh, Y Gu, PD Reynolds, CS Levin Physics in Medicine & Biology 61 (18), 6733, 2016 | 43 | 2016 |
Effects of multiple-interaction photon events in a high-resolution PET system that uses 3-D positioning detectors Y Gu, G Pratx, FWY Lau, CS Levin Medical Physics 37, 5494-5508, 2010 | 34 | 2010 |
Study of electrode design for a CZT-based PET detector Y Gu, CS Levin Physics in Medicine and Biology 59 (11), 2599-2621, 2014 | 25 | 2014 |
Charge collection studies of a high resolution CZT-based detector for PET JL Matteson, Y Gu, RT Skelton, AA Deal, EA Stephan, F Duttweiler, ... 2008 IEEE Medical Imaging Conference, 503-510, 2008 | 25 | 2008 |
Space-indexed dynamic programming: learning to follow trajectories JZ Kolter, A Coates, AY Ng, Y Gu, C DuHadway Proceedings of the 25th international conference on machine learning, 2008 | 23 | 2008 |
Study of a high resolution, 3-D positioning cross-strip cadmium zinc telluride detector for PET Y Gu, JL Matteson, RT Skelton, AA Deal, EA Stephan, F Duttweiler, ... 2008 IEEE Medical Imaging Conference, 3596-3603, 2008 | 12 | 2008 |
First acquisition of data from a prototype 3-D position sensitive CZT PET system S Abbaszadeh, Y Gu, U Sikora, CS Levin 2014 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC …, 2014 | 11 | 2014 |
High-Rresolution Small Animal Positron Emission Tomography System Based on 3-D Position Sensitive Cadmium Zinc Telluride Photon Detectors Y Gu Stanford University, 2014 | 8 | 2014 |
Robust detector calibration for a novel PET system based on cross-strip CZT detectors D Vernekohl, S Abbaszadeh, Y Gu, CS Levin IEEE Transactions on Radiation and Plasma Medical Sciences 3 (6), 626-633, 2018 | 7 | 2018 |
Direct conversion semiconductor detectors in positron emission tomography JW Cates, Y Gu, CS Levin Modern Physics Letters A Particles and Fields; Gravitation; Cosmology and …, 2015 | 7 | 2015 |
Portable GNSS Baseband Logging M Quigley, P Abbeel, DSD Lorenzo, Y Gu, S Bolouki, D Akos, AY Ng Institute of Navigation (ION) 2007 GNSS Conference, 2007 | 7 | 2007 |
Characterization of Inter-detector Effects in a 3-D Position-Sensitive Dual-CZT Detector Modules for PET Y Gu, CS Levin 2012 IEEE Medical Imaging Conference, 2012 | 6 | 2012 |
Effects of photon multiple interactions in a high resolution PET system that uses 3-D positioning detectors Y Gu, P G., FWY Lau, CS Levin 2008 IEEE Medical Imaging Conference, 3814-3819, 2008 | 5* | 2008 |
Studies of electrode design for a sub-mm resolution 3-D position sensitive CZT PET detector Y Gu, CS Levin 2011 IEEE Medical Imaging Conference, 2303-2305, 2011 | 4 | 2011 |
Real-time dynamic signature verification B Anderson, Y Gu, P C., D Rubin Elektron, 2002 | 2 | 2002 |
Enhanced data analysis for improved energy resolution of a CZT-based PET system D Vernekohl, S Abbaszadeh, Y Gu, CS Levin 2015 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC …, 2015 | 1 | 2015 |
Positioning of Multiple Photon Interaction Events in Cross Strip Cadmium Zinc Telluride Detectors for PET PL Rajbhandary, Y Gu, CS Levin arXiv preprint arXiv:1804.00592, 2018 | | 2018 |
Ultra-high Resolution Small Animal Positron Emission Tomography System with Adjustable Field-of-view Based on Novel 3-D Positioning Cadmium Zinc Telluride Detectors Y Gu, CS Levin World Molecular Imaging Congress 2011, 2011 | | 2011 |
Spatial Resolution Improvement by Maximum Likelihood Estimation in a 3-D Positioning CZT Detector for High-resolution PET Y Gu, G Chinn, A Bousselham, CS Levin 2010 IEEE Medical Imaging Conference, 2010 | | 2010 |