Ocoleanu Constantin Florin
Ocoleanu Constantin Florin
Sef lucrari, Universitatea din Craiova, Facultatea de Inginerie Electrica
Verified email at elth.ucv.ro
Title
Cited by
Cited by
Year
Numerical modeling of DC busbar contacts
I Popa, AI Dolan
2012 13th International Conference on Optimization of Electrical and …, 2012
212012
Temperature investigation in contact pantograph-AC contact line
CF Ocoleanu, I Popa, G Manolea, AI Dolan, S Vlase
vol 3, 154-163, 2009
142009
Temperature investigations in two type of crimped connection using experimental determinations
CF Ocoleanu, AI Dolan, G Cividjian, S Teodorescu
International Journal of Mechanical, Aerospace, Industrial and Mechatronics …, 2014
102014
Solutions for quality pre-control of crimp contacts used in electric power systems and electrical machines
CF Ocoleanu, G Cividjian, G Manolea
3rd International Symposium on Environmental Friendly Energies and …, 2014
72014
Numerical study of thermal field of pantograph contact strip-contact line wire assembly
CF Ocoleanu, G Manolea, G Cividjian, CA Bulucea
Adv. Energy Planning, Environ. Educ. Sources 38 (4), 139-143, 2010
72010
Cooling system for photovoltaic module
IL Alboteanu, CF Ocoleanu, CA Bulucea
Recent Researches in Enviromental and Geolegical Sciences, 133-138, 2012
62012
Experimental study of contact resistance variations for pantograph-contact line contact
CF Ocoleanu, G Manolea, G Cividjian
Proceedings of WSEAS International Conference on Risk Management …, 2010
62010
Remote monitoring system of the temperature of detachable contacts from electric cells
L Alboteanu, F Ocoleanu, A Novac, G Manolea
Annals of the University of Craiova, Electrical Engineering series, 1842-4805, 2010
62010
Short circuits faults diagnosis for the rectifier based on the analytic model method
V Ivanov, M Brojboiu, S Ivanov, F Ocoleanu
2016 International Conference and Exposition on Electrical and Power …, 2016
52016
Crimped connections heat transfer coefficient law determination using experimental and numerical results
CF Ocoleanu, I Popa, AI Dolan, V Ivanov
2014 International Conference on Applied and Theoretical Electricity (ICATE …, 2014
52014
EXPERIMENTAL VALIDATION OF NUMERICAL RESULTS CORESPONDING TO CATENARY CONTACT WIRE TEMPERATURE
CF OCOLEANU, G MANOLEA, I POPA
A A 2 (1), 1, 2011
52011
Technological solution for increasing the quality of crimped connections
CF Ocoleanu, G Cividjian, G Manolea
2015 IEEE 1st International Forum on Research and Technologies for Society …, 2015
42015
Manolea Gh., Dolan AI
CF Ocoleanu, I Popa
Temperature measurement in contact pantograph-AC contact line, 184-188, 0
4
Current distribution in crimped connections
GA Cividjian, F Ocoleanu, G Manolea
2014 International Conference on Applied and Theoretical Electricity (ICATE …, 2014
32014
Iterative experimental procedure for determining of heat transfer coefficient of Catenary's contact line wire
CF Ocoleanu, I Popa, G Manolea
Advances in Production, Automation and Transportation Systems, WSEAS 2013 …, 2013
32013
Temperature Measurement in Contact Pantograph- AC Contact Line
CF Ocoleanu, I Popa, G Manolea, AI Dolan
WSEAS International Conference. Proceedings. Mathematics and Computers in …, 2009
32009
A new approach to determine heat transfer coefficient of crimped connections
CF Ocoleanu, I Popa
2018 International Conference on Applied and Theoretical Electricity (ICATE …, 2018
22018
Analysis of Crimped Connections Heat Transfer Coefficient Using Experimental and Numerical Determinations
CF Ocoleanu, I Popa
Annals of the University of Craiova, Electrical Engineering series, 81-86, 2017
22017
Design of a virtual intrument in LabVIEW for crimped connection temperature measurement
CF Ocoleanu, G Manolea
2016 International Conference on Applied and Theoretical Electricity (ICATE …, 2016
22016
Development of a virtual instrument for humidity measurement
CF Ocoleanu, V Ivanov
2016 International Conference on Applied and Theoretical Electricity (ICATE …, 2016
22016
The system can't perform the operation now. Try again later.